ENHANCING COPPER REMOVAL THROUGH INTEGRATED CAPACITIVE DEIONIZATION WITH HETEROGENEOUS CATION EXCHANGE MEMBRANE

Authors

  • Thong Nguyen Tan School of Biochemical Engineering and Technology, Sirindhorn International Institute of Technology, Thammasat University
  • Achira Patcharanuruksakorn School of Biochemical Engineering and Technology, Sirindhorn International Institute of Technology, Thammasat University
  • Artittayaporn Kerdchouay School of Biochemical Engineering and Technology, Sirindhorn International Institute of Technology, Thammasat University
  • Pichamon Bunraksa School of Biochemical Engineering and Technology, Sirindhorn International Institute of Technology, Thammasat University
  • Sandhya Babel School of Biochemical Engineering and Technology, Sirindhorn International Institute of Technology, Thammasat University

DOI:

https://doi.org/10.55766/sujst-2024-02-e04938

Keywords:

Copper, Capacitive deionization, Cation exchange membrane, Heavy metal

Abstract

Capacitive deionization (CDI) is a novel technique to eliminate ions present in the solution. This study was designed to evaluate the impact of cation exchange resin loading on the membrane using the nonsolvent-induced phase inversion method. After optimizing the resin loading on the membrane, the prepared membrane was employed for the membrane capacitive deionization (MCDI). A concentration of 500 mg.L-1 Cu2+ was used as a test contaminant in the CDI system to study Cu2+ removal and recovery at different voltages. Results showed that resin loading substantially influenced the membrane structure and enhanced the Cu2+ removal by the CDI technique. The presence of cation exchange resin on the membrane was found by the appearance of a peak at 1,007 cm-1, 1,035 cm-1, and 1,128 cm-1 in the FTIR spectra of the –SO3 group, which became more significant as the amount of resin increased. The prepared membrane’s water uptake and ion exchange capacity increased as the quantity of resins loaded onto the membrane increased. When monitoring a current-time graph during CDI tests, an adsorption amount of 6.9 mg.g-1 of Cu2+ and recovery efficiency of 51.7 % at the 10th cycle in the MCDI cell was observed for M20 (20% by wt resin). Using the prepared membrane in the CDI system has the potential to remove Cu2+ from the solution selectively.

References

Cheng, Y., Hao, Z., Hao, C., Deng, Y., Li, X., Li, K., and Zhao, Y. (2019). A review of modification of carbon electrode material in capacitive deionization. RSC Advances, 9(42):24401-24419. https://doi.org/10.1039/C9RA04426D

Fairbrother, A., Wenstel, R., Sappington, K., and Wood, W. (2007). Framework for metals risk assessment. Ecotoxicology and Environmental Safety, 68(2):145-227. https://doi.org/10.1016/j.ecoenv.2007.03.015

Fu, F. and Wang, Q. (2011). Removal of heavy metal ions from wastewaters: a review. Journal of Environmental Management, 92(3), 407-418. https://doi.org/10.1016/j.jenvman.2010.11.011

Hosseini, S.M., Rahzani, B., Asiani, H., Khodabakhshi, A.R., Hamidi, A.R., Madaeni, S.S., Moghadassi, A.R., and Seidypoor, A. (2014). Surface modification of heterogeneous cation exchange membranes by simultaneous using polymerization of (acrylic acid-co-methyl methacrylate): Membrane characterizationin desalination process. Desalination, 345:13-20. https://doi.org/10.1016/j.desal.2014.04.028

Khoiruddin, Ariono, D., Subagjo, and Wenten, I.G. (2017). Surface modification of ion‐exchange membranes: Methods, characteristics, and performance. Journal of Applied Polymer Science, 134(48):45540. https://doi.org/10.1002/app.45540

Kumar, P., Dutta, K., Das, S., and Kundu, P.P. (2014). Membrane prepared by incorporation of crosslinked sulfonated polystyrene in the blend of PVdF-co-HFP/Nafion:

A preliminary evaluation for application in DMFC. Applied Energy, 123:66-74. https://doi.org/10.1016/j.apenergy.2014.02.060

Luo, H., Agata, W.-A.S., and Geise, G.M. (2020). Connecting the ion separation factor to the sorption and diffusion selectivity of ion exchange membranes. Industrial and Engineering Chemistry Research, 59(32):14189-14206. https://doi.org/10.1021/acs.iecr.0c02457

McNair, R., Szekely, G., and Dryfe, R.A.W. (2021). Ion-exchange materials for membrane capacitive deionization. ACS ESandT Water, 1(2):217-239. https://doi.org/10.1021/acsestwater.0c00123

Mondal, R., Pal, S., Bhalani, D.V., Bhadja, V., Chatterjee, U., and Jewrajka, S.K. (2018). Preparation of polyvinylidene fluoride blend anion exchange membranes via non-solvent induced phase inversion for desalination and fluoride removal. Desalination, 445:85-94. https://doi.org/10.1016/j.desal.2018.07.032

Nguyen Tan, T., Babel, S., Bora, T., Sreearunothai, P., and Laohhasurayotin, K. (2024). Preparation of heterogeneous cation exchange membrane and its contributions in enhancing the removal of Ni2+ by capacitive deionization system. Chemosphere, 350:141115. https://doi.org/10.1016/j.chemosphere.2024.141115

Qasem, N.A.A., Mohammed, R.H., and Lawal, D.U. (2021). Removal of heavy metal ions from wastewater:

a comprehensive and critical review. npj Clean Water, 4(1):36. https://doi.org/10.1038/s41545-021-00127-0

Srivastava, N.K. and Majumder, C.B. (2008). Novel biofiltration methods for the treatment of heavy metals from industrial wastewater. Journal of Hazardous Materials, 151(1):1-8. https://doi.org/10.1016/j.jhazmat.2007.09.101

Tan, T.N. and Babel, S. (2023). Unravelling the key contribution of a modified zinc oxide nanostructures on activated carbon cloth material for removal of Cu2+ in different configurations of capacitive deionization system. Journal of Water Process Engineering, 56:104268. https://doi.org/10.1016/j.jwpe.2023.104268

Zare, S. and Kargari, A. (2018). Membrane properties in membrane distillation. In: Emerging Technologies for Sustainable Desalination Handbook, Elsevier, p. 107-156. https://doi.org/10.1016/B978-0-12-815818-0.00004-7

Zhang, Y., Srimuk, P., Aslan, M., Gallei, M., and Presser, V. (2020). Polymer ion-exchange membranes for capacitive deionization of aqueous media with low and high salt concentration. Desalination, 479:114331. https://doi.org/10.1016/j.desal.2020.114331

Zhang, Y., Zou, L., Ladewig, B.P., and Mulcahy, D. (2015). Synthesis and characterisation of superhydrophilic conductive heterogeneous PANI/PVDF anion-exchange membranes. Desalination, 362:59-67. https://doi.org/10.1016/j.desal.2015.02.004

Downloads

Published

2024-05-23

How to Cite

Nguyen Tan, T., Patcharanuruksakorn, A., Kerdchouay, A., Bunraksa, P., & Babel, S. (2024). ENHANCING COPPER REMOVAL THROUGH INTEGRATED CAPACITIVE DEIONIZATION WITH HETEROGENEOUS CATION EXCHANGE MEMBRANE. Suranaree Journal of Science and Technology, 31(2), 030185(1–7). https://doi.org/10.55766/sujst-2024-02-e04938

Issue

Section

Research Article

Categories