IMAGE ENHANCEMENT TECHNIQUES FOR TELE-SLIT LAMP MICROSCOPY
Abstract
Ophthalmologists need an Eye-Tele analyzer that has a high-resolution image and no light reflection.A Slit lamp microscope, which is the main part of Eye-Tele analyzer, can be improved by implementing the function of an auto focus system, eye-tracking system, and image enhancement method. The focus position is the position that gives the maximum focus value. However there flection of light from the slit lamp can cause an error in finding the focus value algorithm. The reflection must first be identified and removed before calculating the focus values. The simulation result shows that the proposed algorithm can give the right focus position with trade off on computational time. Since the human eye is a spherical shape, slit lamp microscopy will focus only on a small part of the eye or only on the area of interest. To get an entirely sharp image, where all parts of the eye are in focus, a set of sharp eye images in different areas is needed to make the image mosaic method. This mosaic method can improve the resolution of the overall image. However, some sets of eye images are taken under different lighting conditions, which can lead to false mosaicking.The processing time is extremely long to process. To solve this problem, the gradient orientation pattern matching technique (GOPM) is used to eliminate the undistributed light intensity. The coarse-to-fine gray-scale matching strategy is introduced to reduce the computational time. The results show that the uses of GOPM help the mosaicking process, to give an accurate matching position which is very important for the image enhancement process. Also, the processing time is remarkably reduced.
References
Asmuth, J., Madjarov, B., Sajda, P., and Berger,J.W. (2001). Mosaicking and enhancement of slit lamp biomicro scopic fundus images.Br. J. Ophthalmol, 85:563-565.
Gierl, C., Kondo, T., Voos, H., KongprawechnonW., and Phoojaruenchanachai, S. (2007a).Image processing based auto focus system for remote eye diagnostics. the 29thAnnual International Conference of theIEEE Engineering in Medicine and Biology Society (IEEE EMBC 2007);August 26 –27, 2007; Lyon, France.
Gierl, C., Kondo, T., Voos, H., KongprawechnonW., and Phoojaruenchanachai S. (2007b).Image processing algorithms for an auto-focus system for slit lamp microscopy.Lecture Notes in Computer Science(Advanced Concepts for Intelligent Vision System), 4678:909-919.
Groen, F.C.A., Young, I.T., and Ligthart, G.(1985). A comparison of different focus functions for use in autofocus algorithms.Cytometry, 6:81-89.
Jaiwat, P., Sirijuntanun, T., Kondo, T.,Kongprawechnon, W. and Tungpimolrut,K. (2009). Auto focusing and image enhancement techniques for tele-slit lamp microscope. the 2nd Biomedical Engineering International Conference(BMEiCON); August 13-14, 2009;Phuket, Thailand.
Jiewpaibul, P., Piriyanont, B., Kongprawechnon,W., Kondo, T., and Phoojaruenchanachai,S. (2008). Fuzzy controller and image enhancement for slit lamp microscopy.Proceedings of the 5th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTICON2008); May 14- 17, 2008; Krabi, Thailand, p. 521 – 524.
Kondo, T. and Kongprawechnon, W. (2009a).A block matching technique using unit gradient vectors. IAPR Conference on Machine Vision Applications (MVA2009), May, 2009; Japan, 390-393.
Kondo, T. and Kongprawechnon, W. (2009b).A matching technique using gradient orientation patterns. Thammasat International Journal of Science and Technology (TIJSAT), 14 (13):41-55.
Subbarao M., Choi T., and Nikzad, A. (1993).Focusing techniques. J. Opt. Eng., 32:2824-2836.
Tanta-ngai, K., Leelasawassuk, T., Komeswarakul,P., and Chaopramualkul, W. (2008). Eye Tele-Analyzer system. proceedings of the 5th International Conference ElectricalEngineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON 2008); May14-17, 2008; Krabi, Thailand, 621-624.