EXPERIMENTAL INVESTIGATION ON SQUARE STEEL TUBED RC COLUMNS UNDER AXIAL COMPRESSION
Keywords:
Tubed RC column, concrete-filled steel tube column, axial compression, reinforced concrete columnAbstract
This paper reports an experimental study on the behaviors and modes of failure of the square steeltubed RC columns subjected to concentrically axial load, applied directly to the RC core. The mainvariables were the compressive strength of the concrete, the wall thickness of the steel tube and the tiespacing. All square columns were 150 mm in width and 750 mm in height. A total of 36 specimens,including 24 tubed RC columns and 12 reference RC columns, were tested. It was found that the tubedRC columns have a ductile-like with strain hardening, elastic-perfectly plastic and strain-softeningbehavior. The mode of failure of the columns is in progressive mode with very large axial deformability.The wall thickness of the steel tube and the compressive strength of concrete are the major factors,influencing the behaviors, axial compressive capacity and modes of failure of the columns. Since thebehaviors of the column are different from those of the CFT column, the ACI 318 design equationconsiderably overestimates the axial compressive capacity of the column. Finally, based on the resultsobtained from this study, the design equation for the tubed RC column was proposed.
References
ACI Committee 318. (2002). Building CodeRequirements for Structural Concrete(ACI 318-02). American ConcreteInstitute. Detroit.
ASTM C39-96. (1996). Standard Test Methodsfor Compressive Strength of CylindricalConcrete Specimens. Annual Book ofASTM Standard. Philadelphia: AmericanSociety for Testing and Materials.
ASTM E8-98. (1998). Standard Test Methodsfor Testing of Metallic Materials. AnnualBook of ASTM Standard. Philadelphia:American Society for Testing andMaterials.
Han, L.H., Liu, W., and Yang, F.U. (2008).Behavior of thin walled steel tube confinedconcrete stub columns subjected to axiallocal compression. Thin Walled Struct,46(2):155-164.
Priestley, M.J.N., Seible, F., Xiao, Y., and Verma,R. (1994b). Steel jacket retrofitting of RCbridge columns for enhanced shearstrength: test result and comparison withtheory. ACI Struct., 91(5):537-551.
Saw, H.S. and Liew, J.Y.R. (2000). Assessmentof current methods for the design ofcomposite columns in buildings. J. Constr.Steel. Res., 53:121-147.
Seangatith, S. and Thumrongvut, J. (2008)Investigation on square tubed concretecolumns subjected to axial compressiveloads. KKU Eng J, 35(1):81-99.
Shanmugam, N.E. and Lakshmi, B. (2001). Stateof the art report on steel-columncomposite columns. J. Constr. Steel. Res.,57:1,041-1,080.
Tomii, M., Sakino, K., Watanabe, K., and Xiao,Y. (1985). Lateral load capacity ofreinforced concrete short columns confinedby steel tube. Proceedings of InternationalSpeciality Conference on Concrete FilledSteel Tubular Structures; August, Harbin,China, p. 19-26.
Xiao, Y., He, W., and Choi, K. (2005). Confined concrete filled tubular columns. J StructEng-ASCE, 131(3):488-497.








