Instability Mitigation of AC-DC Power System feeding Controlled Buck-Boost By using Loop-Cancellation Technique
Main Article Content
Abstract
The paper presents the instability mitigation of three-phase full bridge diode rectifier feeding buck-boost converter using loop cancellation technique. This technique is used to overcome the instability operation. The mathematical model of the proposed system derived from the DQ method and the generalized state-space averaging method (GSSA) is used with the eigenvalue theorem for stability studies. The intensive time-domain simulation of MATLAB is validate the stable point predicted from the theory. The stabilization results show that the unstable system due to a constant power load can become back to stable system by using the proposed technique.
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Journal of TCI is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence, unless otherwise stated. Please read our Policies page for more information...
References
A. Emadi, M. Ehsani and J. M. Miller, Vehicular Electric Power Systems: Land, Sea, Air, and Space Vehicle.New York: Marcel
Dekker, 2003.
A. M. Rahimi and A.Emadi, "An analytical investigation of DC/DC power electronic converters with constant power loads in vehicular
power systems," IEEE Trans. Veh. Technol., vol. 58, no. 6, pp. 2689-2702, Jul. 2009.
A. Emadi, A. Khaligh, C. H. Rivetta and G. A. Williamson,"Constant power loads and negative impedance instability in automotive systems: Definition, modeling, stability, and control of power electronic converters and motor drives, "IEEE Trans. Veh. Technol., vol. 55, no. 4, pp. 1112-1125, Jul. 2006.
K-N. Areerak, S.V. Bozhko, G.M. Asher, L. De Lillo, and D.W.P. Thomas, "Stability Study for a Hybrid AC-DC More-Electric
Aircraft Power System", IEEE Trans. on Aerospace and Electronic Systems, vol. 48, no. 1, January 2012, pp. 329-347.
T.Sopapirm, K-N.Areerak, and K-L. Areerak, “Stability Analysis of AC-DC Distribution System with Six-Pulse Diode Rectifier and Multi-Converter Power Electronic Loads”, International Review of Electrical Engineering (I.R.EE)., Vol. 6, n. 7 November-December 2011, pp. 2919-2928.
A.M. Rahimi, G.A. Williamson and A. Emadi, “Loop-cancellation technique: a novel nonlinear feedback to overcome the destabilizing
effect of constant-power loads,” IEEE Trans. Veh. Technol., vol. 59, no. 2, pp. 650-661, Feb. 2010.