Development of Carbon Dioxide Concentration Control System for an Air-Conditioned Room

Authors

  • Poonyasiri Boonpeng Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Lanna, Chiang Mai, Thailand
  • Krisda Yingkayun Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Lanna, Chiang Mai, Thailand
  • Uten Boonliam Tenergy Innovation Co., Ltd., Science and Technology Park, Chiang Mai, Thailand
  • Chawaroj Jaisin School of Renewable Energy, Maejo University, Chiang Mai, Thailand

Keywords:

Carbon Dioxide Concentration Control for an Air-conditioned Room, Ventilation, Indoor Air Quality

Abstract

The research aimed to develop a carbon dioxide concentration control system for an air-conditioned room by using step control conditions for ventilation rate according to the CO2 level. In addition, the accumulation of CO2 and ventilation rate of the ventilation system were systematically investigated. In the case when the control system started at the CO2 concentration of 1,000 ppm and the accumulation of CO2 concentration was 25.92 ppm/min for 120 min, the average concentration over the period of 60-120 min turned out to be 1,528.2 ppm. At such conditions, the consumption of total real power was 4.07 kWh, which was 1.39 times compared to the case with no ventilation. When the step control condition of the control system changed to start at the concentration of 750 ppm, the average concentration of 1,362 ppm and the power consumption of 4.19 kWh were noted; this represented an increase in the power consumption of 1.43 times. Finally, when using the maximum ventilation rate for 120 min, the average concentration of 919 ppm and the power consumption of 6.98 kWh were noted; the power consumption increased by 2.4 times. In the case where the CO2 level of around 1,500 ppm could be accepted, operation of control system with step control condition for ventilation led to the saving of the power consumption of approximately 40%.

References

Kanjanakrajang, A. and Chuaybamroong, P., 2017, “Measurements of Carbon Dioxide to Determine the Ventilation Effectiveness in the Classroom,” Thai Science and Technology Journal, 25 (6), pp. 960-974. (In Thai)

Chindapol, S., 2019, “Indoor Environmental Quality in a Classroom: Faculty of Architecture, Chiang Mai University,” The Journal of Architectural/Planning Research and Studies, 16 (1), pp. 93-105. (In Thai)

Schibuola, L., Scarpa, M. and Tambani, C., 2016, “Natural Ventilation Level Assessment in a School Building by CO2 Concentration Measures,” Energy Procedia, 101, pp. 257-264.

Ministry of the Environment Housing and Building Department, 2003, Indoor Climate and Ventilation of Buildings Regulations and Guidelines 2003, Decree of the Ministry of the Environment on the indoor Climate and ventilation of buildings, Helsinki, pp. 33-38.

Persily, A., 2020, “Quit Blaming ASHRAE Standard 62.1 for 1000 ppm CO2,” Proceedings of the 16th Conference of the International Society of Indoor Air Quality and Climate, November 1-4, Korea, pp. ABS-0445.

Kesornthong, S., 2006, Sick Building Syndrome, 1st ed., Klaimor, Bangkok, 193 p. (In Thai)

Daisey, M.J., Angell, J.W. and Apte, M.G., 2003, “Indoor Air Quality, Ventilation and Health Symptoms in Schools: An Analysis of Existing Information,” Indoor Air, 13, pp. 53-64.

ASHRAE, 2019, ANSI/ASHRAE Standard 62.1- 2019 Ventilation for Acceptable Indoor Air Quality, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, 87 p.

MacNaughton, P., Spengler, J., Vallarino, J., Santanam, S., Satish, U. and Allen, J., 2016, “Environmental Perceptions and Health before and after Rrelocation to a Green Building,” Building and Environment, 104, pp. 138–144.

Vehviläinen, T., Lindholm, H., Rintamäki, H., Pääkkönen, R., Hirvonen, A., Niemi, O. and Vinha, J., 2016, “High Indoor CO2 Concentrations in an Office Environment Increases the Transcutaneous CO2 Level and Sleepiness during Cognitive Work,” Journal of Occupational and Environmental Hygiene, 13, pp. 19–29.

Satish, U., Mendell, M.J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S. and Fisk, W.J., 2012, “Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance,” Environmental Health Perspectives, 120, pp. 1671–1677.

Allen, J.G., MacNaughton, P., Cedeno-Laurent, J.G., Cao, X., Flanigan, S., Vallarino, J., Rueda, F., Donnelly-McLay, D. and Spengler, J.D., 2018, “Airplane Pilot Flight Performance on 21 Maneuvers in a Flight Simulator under Varying Carbon Dioxide Concentrations,” Journal of Exposure Science & Environmental Epidemiology, 29, pp. 457–468.

Carreiro-Martins, P., Viegas, J., Papoila, A.L., Aelenei, D., Caires, I., Araújo-Martins, J., Gaspar-Marques, J., Cano, M.M., Mendes, A.S., Virella, D., Rosado-Pinto, J., Leiria-Pinto, P., Annesi-Maesano, I., Neuparth, N., 2014, “CO2 Concentration in Day Care Centres is Related to Wheezing in Attending Children,” European Journal of Pediatrics, 173, pp. 1041–1049.

Centers for Disease Control and Prevention, Carbon dioxide Immediately Dangerous to Life or Health Concentrations (IDLH) [Online], Available: https://www.cdc.gov/niosh/idlh/124389.html. [27 June 2021]

Rice, S.A., 2003, “Health Effects of Acute and Prolonged CO2 Exposure in Normal and Sensitive Populations,” Proceedings of the Second Annual Conference on Carbon Sequestration, 5-8 May 2003, Virginia, pp. RICE 2– RICE 7.

Azuma, K., Kagi, N., Yanagi, U. and Osawa, H., 2018, “Effects of Low-Level Inhalation Exposure to Carbon Dioxide in Indoor Environments: a Short Review on Human Health and Psychomotor Performance,” Environment International, 121, pp. 51-56.

Blanco, A. and Blanco, G., 2017, “Metabolism,” pp. 275-281, in Coulthurst, F. (Ed.), Medical Biochemistry, Academic Press, London.

Blanco, A. and Blanco, G., 2017, “Carbohydrate Metabolism,” pp. 283-323, in Coulthurst, F. (Ed.), Medical Biochemistry, Academic Press, London.

Batog, P. and Badura, M., 2013, “Dynamic of Changes in Carbon Dioxide Concentration in Bedrooms,” Procedia Engineering, 57, pp. 175-182.

Braun, S.R., 1990, "Respiratory Rate and Pattern,” Clinical Methods, The History, Physical, and Laboratory Examinations, pp. 226-323, in Walker, H.K, Hall, W.D and Hurst, J.W. (Eds.), Butterworths, Boston.

Huang, Q., Marzouk, T., Cirligeanu, R., Malmstrom, H., Eliav, E. and Ren, Y.F., 2021, “Ventilation Assessment by Carbon Dioxide Levels in Dental Treatment Rooms,” Journal of Dental Research, 100 (8), pp. 810-816.

Fisk, W.J., Black, D. and Brunner, G., 2012, “Changing Ventilation Rates in U.S. Offices: Implications for Health, Work Performance, Energy, and Associated Economics,” Building and Environment, 47, pp. 368-372.

Kurnitski, J., 2020, “Ventilation Rate and Room Size Effects on Infection Risk of COVID-19,” REHVA European HVAC Journal, 57, pp. 26-31.

Rachapradit, N., Poowaruttanawiwit, P. and Kosum, T., 2020, “Improvement of Indoor Air Quality with Ventilation During Nighttime in Bedrooms in Residential House,” Journal of Industrial Education, 14 (1), pp. 106-123. (In Thai)

Downloads

Published

2022-06-30

How to Cite

Boonpeng, P., Yingkayun, K., Boonliam, U., & Jaisin, C. (2022). Development of Carbon Dioxide Concentration Control System for an Air-Conditioned Room. Science and Engineering Connect, 45(2), 215–233. retrieved from https://ph04.tci-thaijo.org/index.php/SEC/article/view/10281

Issue

Section

Research Article